| Stock Code: 688115
| SC: 688115

SG2163 Vector Network Analyzer

SG2163 Vector Network Analyzer

  • Host unit with four RF test ports
  • Testing dynamic range of 120 dB or more
  • Low background noise down to -125 dBm/Hz
  • User interface based on the Windows system
  • Measurement time per point better than 70 microseconds
  • Supports RF signal testing up to 8.5 GHz
  • Supports measurements such as S-parameters, Smith charts, and frequency response

Description

The SG2163 Vector Network Analyzer (VNA) is a four-port RF measurement instrument capable of providing measurements of RF signal transmission characteristics and reflection characteristics. This product consists of a main unit and a control and display interface based on the Windows operating system, with data transmission utilizing a Gigabit Ethernet interface.It finds wide applications in RF research,testing, and production manufacturing in fundamental industries and fields such as microwave devices,materials science, and electronic communications.

Product features

  • Host unit with four RF test ports
  • Testing dynamic range of 120 dB or more
  • Low background noise down to -125 dBm/Hz
  • User interface based on the Windows system
  • Measurement time per point better than 70 microseconds
  • Supports RF signal testing up to 8.5 GHz
  • Supports measurements such as S-parameters, Smith charts, and frequency response

Application Scope

sg2163 vector network analyzer

Specifications

Number of test ports 4 (2 or more ports are custmizable)
System impedance 50 ohm
Connector of test ports SMA female (SMA or N is custmizable)
Damage level +26 dBm , 35 VDC
Frequency range 100 KHz to 8.5 GHz (custmizable)
Frequency resolution < 1 Hz
Power range -55 dBm to +5 dBm
Power accuracy ±1.5 dB
Power resolution 0.05 dB
Dynamic range 120 dB
Measurement bandwidth(IFBW) 10 Hz to 1 MHz
Harmonic distortion -20 dBc
Non-harmonic spurious -20 dBc
Level for 0.1 dB compression >+5 dBm
Noise floor -125 dBm/Hz
Trace noise (IFBW 1 KHz) 0.003 dBrms / 0.05 degrms
Measurement Accuracy of transmission ±0.2 dB @ 0 dB to +10 dB
±0.1 dB @ -10 dB to 0 dB
±0.2 dB @ -40 dB to -10 dB
±1.0 dB @ -65 dB to -40 dB
±2.0 dB @ -85 dB to -65 dB
Measurement Accuracy of reflection ±0.4 dB @ -15 dB to 0 dB
±1.0 dB @ -25 dB to -15 dB
±3.0 dB @ -35 dB to -25 dB
Directivity 45 dB
Source match 40 dB
Load match 45 dB
Transmission tracking ±0.1 dB / ±1°
Reflection tracking ±0.1 dB / ±1°
Number of measurement points 2 to 16001
Measurement time per data point 70 us (typical value)
Power 12 VDC ± 5%
Current 3.4 A, maximum
Power consumption 36 VA (typical value)
Dimensions 230 mm * 370 mm * 70 mm (with chassis or modularized is custmizable)
Weight 5.0 kg
Operating temperature range 0 °C to + 50 °C
Maximum altitude 2,000 m (at 25 °C ambient temperature)
Relative humidity range 10% to 90% R.H. , no condensation